Bauhu prefabricated construction Bauhu prefabricated modular site building construction Bauhu prefabricated modular buildings Bauhu light steel frame homes Bauhu cube container accommodation Bauhu prefabricated low cost camp housing

P R E F A B R I C A T E D
H O U S E S

A wide range of prefabricated buildings offering low cost housing solutions and rapid construction times...

MORE..

T E M P O R A R Y
A C C O M M O D A T I O N

Modular, multi purpose, stackable, demountable container type accommodation for work sites and temporary housing...

MORE..

M O D U L A R
B U I L D I N G S

Modular, factory engineered constructions ideal for hotel and student accommodation, offering flexibility and reducing build costs...

MORE..

S T E E L  F R A M E
H O M E S

Light steel frame construction system offers high building performance and stylish, economical homes...

MORE..

C O N T A I N E R  C U B E
H O U S I N G

Container based housing provides rapid and comfortable accommodation in remote locations...

MORE..

C A M P  &  S I T E
A C C O M M O D A T I O N

Low cost, sandwich panel system, multiple housing custom designed to customer specification and local climatic conditions...

MORE..
Menu
BAUHU - Prefabricated buildings
INTRODUCTION
FAQs
PROJECT PHOTOS
ASSEMBLY PHOTOS
PRODUCTION PHOTOS
TECHNICAL SPECIFICATIONS
PRICES

Prefabricated homes from BAUHU




Light steel frame homes from BAUHU
Bauhu Homes STEEL FRAME HOMES
Maisons ossature metallique
Bauhu Homes CUSTOM DESIGN
Maisons  sur mesure
Bauhu Homes BAÜHU CONSTRUCT
Maisons modulaires ossature metallique
Bauhu Homes BAÜHU CUBES
Flat pack, multi purpose, modular buildings
Bauhu Homes COMMERCIAL BUILDINGS

Renewable technology energy saving options from BAUHU
SOLAR ENERGY
HEAT PUMPS
LOW ENERGY LIGHTING
SECURITY
AIR CONDITIONING
   English English   Español  Español Français  Francais

Norway - Cool homes from Bauhu world wide  belgium - Cool homes from Bauhu world wide   Suisse - Cool homes from Bauhu world wideGermany - Italy - Cool homes from Bauhu world wide Italy - Cool homes from Bauhu world wide  

 
 
PREFABRICATED HOMES | COMMERCIAL BUILDINGS | BAÜHU CUBES | Contact  
 

Prefabricated Buildings / Technical Specifications

Prefabricated buildings /  Technical Specifications

1- GENERAL SYSTEM DESCRIPTION:

PRODUCTION TECHNOLOGY : DIN EN 10326 standard thin section galvanized C and U profiles, produced by S320GD+Z,+AZ quality no:1332, S350GD+Z,+AZ quality no:1335, and/or quality no: 1322
steel material produced in Cad-Cam controlled fully automatic continued roll -forming machines. Production does not involve welding.

ASSEMBLY: Wall Panels, Roof Beam, Beams and Mezzanine are assembled with Special Screws and Bolts without Welding. This allows
for multiple Dis-assembly - Assembly.

STATIC CALCULATI
ONS: Calculations regarding compliance of the building to its purpose, and seismic and static calculations depending on the region, are made by Sap2000, CFS, STA4CAD, BRICSCAD, HAYESCAD programs in accordance with the load values defined in project and standards, as well as European Standards and/or International Standards as defined in item 3.

HEAT (CLIMATE) CALCULATION: Outer Wall and Roof are detailed in consideration with European climatic conditions of the region and to comply with recommended Insulation Values. There is insulation material between C profiles of the panels. Therefore Heat Balance is not required.

ELECTRICAL INSTALLATION: Inner and Outer Wall Panels are produced
with conduit in the factory for wiring during installation.

FINISHINGS: For Panel connections; PVC T profiles are used in Inner Surfaces, 30 mm thick cement joint plate (Betopan) laths are used in outer surfaces. Outer surface coating is CE approved (Fire and Water Resistant) Decorative Shield and Sutured Cement board.

2- PREFABRICATED HOUSE SYSTEM, COMPLIANCE STANDARDS:

11372 :Steel Buildings – Light – Generated by Cold Shaped Profiles– Calculation Rules
648 : Calculations and Construction Rules for Steel Buildings 
6793 : Usage and Settlement Loads in Houses and Utilities
498 : Calculation Values for Dimensioning of Construction Elements
7046 : Principles for Construction Design
ENV 1993–1–2 :(Euro code 3) Design of Steel Buildings Volume 1–2: General Rules- Constructional Design Against Fire
4561 : Calculation Rules of Steel Buildings According to Plastic Theory
ENV 1090-1 : Steel Construction Applications –Volume 1:General rules and rules for buildings
ENV 1090-3 : Steel Construction Applications – Volume 3: Additional rules for steel resistant to High Currency.
ENV1998-1: Euro code 8: Projecting Buildings Resistant to Earthquake –Volume 1: General rules , rules for seismic effects and buildings.
EN 10326 : Delivery Terms for plates produced by continuous hot galvanized Construction Steel 
EN 10327 : Delivery Terms for plates produced by continuous hot galvanized, cold shaping purpose, low Carbon Steel
EN 10162 : Steel Profiles – Cold rolled – Technical delivery conditions – Size and section tolerances,
EN 20898 : Mechanical specifications of connection elements
EN 20898-2 : Mechanical specifications of connection elements – Volume 2: Experiment Load Values Determined Nuts—Normal Step

3- DECORATIVE – SHIELDED OUTER WALL DETAIL
Recommended Insulation Values Acc. to TS825 MAINTAINED HEAT INSULATION VALUES
1st Climate Region : 0.80 W/m2K 0.442 W/m2K (Compliant)
2nd Climate Region : 0.60 W/m2K 0.442 W/m2K (Compliant)
3rd Climate Region : 0.50 W/m2K 0.442 W/m2K (Compliant)
4th Climate Region : 0.40 W/m2K 0.398 W/m2K (Compliant)
Outer wall Thickness :100 mm (110 mm for 4th Climate Region)
Outer Surface Coating :12 mm thick, decorative, cemented board (Shielded and decorative sutured) (CE approved)
Heat and Noise Insulation Material: 75 mm thick Polystyrene Foam (EPS)(16kg/m3) 
Fire retardant: “B1” class “flame resistant” material in accordance with DIN 4102.
Carrier Panel construction: Specially shaped Galvanized C Profile.
Cold Bridge prevention: 10 mm water-resistant wooden lath. (20 mm for cold climate region)
Panel Connection System: Galvanized C profile produced one-piece in Cad-Cam controlled continued roll-form machines. (70 mm) (Static calculation: 1 – 4 mm thick)
Outer Wall Inner Coating: 8 mm thick cemented board
Outer Wall Inner Coating Paint: Plasticised Paint (Double Coating)
Outer Wall Outer Coating Paint : Acrylic Paint (Double Coating)
Outer Surface Accessories : 30 mm thick cemented board.
Window Accessories: 30 mm thick cemented board.

4- INTERNAL WALL DETAILS
Internal Wall Thickness: 60 mm
Inner Surface Coating: 8 mm thick cemented board. (CE approved)
Heat and Noise Insulation Material: 44 mm thick Polystyrene Foam (16kg/m3)
(Fire retardant: “B1” class “flame resistant” material in accordance with DIN 4102.)
Carrier Panel Construction: Galvanized C profile produced one-piece in Cad-Cam controlled continued roll-form machines (44 mm) (Static calculation: 1 – 4 mm thick)
Panel Connection System : Connected by special design and detail Galvanized connection elements, bolt and screw without welding.
Decorative PVC T profiles in joints of the panels.
Inner Wall Inner Coating : 8 mm thick cement shiver plate (CE approved)
Inner Wall Inner Coating Paint : Plastic Paint (Double Coating)
Wet Volume Inner Coating :12,5 mm thick Water resistant Plaster Plate (Wr)

5- CEILING ROOF DETAIL (Suture Banded, hidden joints)
Ceiling Roof Coating :12,5 mm thick FX Plaster Plate (WR Water resistant plaster plates in wet areas) Suture band applied in joints.
Insulation Material: 80 mm thick Rolled Fibre (Water resistant due to lack of Hydroscopic and capillary property.)

6- ROOF DETAIL
Recommended European Insulation Values
1st Climate Region :0.50 W/m2K 0.440 W/m2K (Compliant)
2nd Climate Region :0.40 W/m2K 0.361 W/m2K (Compliant)
3rd Climate Region :0.30 W/m2K 0.234 W/m2K (Compliant)
4th Climate Region :0.25 W/m2K 0.234 W/m2K (Compliant)
Roof Coating Alternative–1 : Metal Based Tile Form (Metal Tile) 
Roof Coating Alternative –2 : Shingle
Truss : Specially Shaped galvanized profile
Vapour Balance : HDPE touch fibre cover
Constructive Coating : 11 mm OSB-3 (Compressed fibre wooden plate)
Roof Support System : Made of specially designed galvanized sheet. Connected by bolt and screws without welding.
Insulation Material: 80 mm thick Fibre (14 kg/m3) (For 1st Climate Region)
Insulation Material :100 mm thick Fibre (14 kg/m3) (For 2nd Climate Region)
Insulation Material :160 mm thick Fibre (14 kg/m3) (For 3rd – 4th Climate Region)
Ceiling Roof construction : Specially designed Omega Profiles.
Rain Channel and gully : Square section coat coil painted galvanized stream and drops.
Fringe Coating : 40 cm wide 12 mm thick cement shiver plate

7- DOORS
EXTERNAL DOORS:
Size :890 x 1960 mm
Door : Steel door without furnishing
Door Casing : Cylindrical lock / Metal door knob
INTERNAL DOORS:
Size :840 x1960 mm
Door :American panel ( 40mm ) White
Door Casing :Metal Door Casing (Wooden Door Casing Optional)
Lock / Knob : Embedded Lock / Metal door knob
Door is detailed with 4 cm Handgrip.

8-WINDOWS
Window :90x130 cm PVC material
Housing : SPECIAL PRODUCTION BETOPAN HOUSING
Horizontal window : 60 / 40 cm PVC material

9-GLASS
Window :4+9+4mm heat control coated double glazed unit
Horizontal window :4mm thick frosted glass

10-MEZZANINE SYSTEM
Standard Mezzanines;
Carcass : Formed by combination of steel profile cage panels with special details. Parts like outer walls, inner walls, and beams are made of galvanized steel profiles, and production and assembly do not involve welding.
Upper Coating :16 mm Betopan (cement shiver plate) (CE Approved)
Ceiling Roof Profile :15 Db Noise Absorbing Protector Ceiling Roof Profile and Clips (European originated)
Ceiling Roof :12,5mm thick White ALCIPAN
Insulation :80 mm thick Mattress Fibre ( 14 kg/m3 )
Load : Taking usage purpose of the building into consideration, mobile load  value is assumed in accordance with 200–350-500 kg/m2

11-STAIRS
Carcass: Carcass made of galvanized steel profiles.
Stair Coating: Coloured Polished Beech Coating
Railing: Profile system railing.
Note: Wooden ladder and railing are optional.

12-PAINT
Outer Surface: 2 coats Acrylic outer surface paint
Inner Surface: 2 coats Plastic paint (colours shall be determined by the contractor.)
Ceiling: 2 coats Plastic paint (colours shall be determined by the contractor.)
Note: Textile based Decorative Wallpaper is used instead of Inner Surface Paint upon request.

Color Charts

Please contact us for Color Charts which can be used on all prefabricated buildings.

13-ELECTRICAL INSTALLATION
Cable 250 V
Socket Cables NYM and NYA 3x2,5 mm2
Lighting Cables NYM and NYA 2x1,5 mm2
Lighting Armatures Normal spaces 2x40 FLUORESCENT (LED fittings optional)
Damp spaces Round Globe– Diamond-Shaped
Outer Door Top Outer Globe – Diamond-Shaped
Fuse, fuse boxes – Diamond-Shaped
Electrical Board Contractor’s responsibility.
Telephone Installation Contractor’s responsibility.
Main Line Connection Contractor’s responsibility.
Fuse board : available in all buildings.
NOTE: Stove, Air Conditioner, Electrical Radiator usage should be specified in the project. 
Each heater, air conditioner shall be fed by a separate fuse line.

14-SANITARY INSTALLATION
Pipes (potable water PPRC pipe
Pipes (drain) PVC pipe
Fittings and fixtures:
Sinks 40x50cm freestanding
Sink Tap Taps Sink Overflow.
Sinks Ceramic reservoir
Shower tray 80x80
Shower/bath mixer taps
Cut off taps mounted on the wall.
Kitchen Installation Hot/Cold water inlets. No cabinets in the kitchen.
Main line connection Contractor shall be responsible for drain and potable water main lines and connections.

15-PACKAGING FOR TRANSPORT
Packaging is provided depending on the transportation type (Land, Sea, Air).

16-OTHER
Please contact us for
non standard insulation alternatives, special needs, and additional information.

 

 